liquitec

bio-t®

Inline Process Ports

Housings for installing sensors directly in the pipeline: the measuring port sits on a pipe section with weld ends. Available with clamp acc. DIN32676, with groove connection acc. DIN11864-3 or with Ingold port 25 mm.

3measuring ports: clamp, DIN11864-3, Ingold 25
12bar operating pressure, gases and liquids
DIN04…40nominal size, also ISO and OD acc. DIN11866
Ra < 0.6µm, product contact electropolished

Overview

Measuring in the line. Without dead space.

The inline process port is welded into the pipeline. The measuring port sits flow-optimised in the pipe run, and the sensor connects to the pipe without dead space. Sensors for pH, pressure or temperature, sampling valves or sight glasses can thus be placed in the line.

  • Measuring port clamp acc. DIN32676, groove connection acc. DIN11864-3 or Ingold port 25 mm
  • Pipe standards DIN, ISO and OD acc. DIN11866
  • Pipe connection with weld ends, other connections by arrangement
  • For gases and liquids up to 12 bar
  • Product contact 1.4435 (316L), special materials acc. ordering key
  • Product-contact surfaces electropolished, Ra < 0.6 µm
  • Product-contact parts marked with article number, material and heat number
  • Inspection certificate 3.1 for product-contact parts

Versions

Three connections, one principle.

Clamp acc. DIN32676

clamp 50.5 or 64 mmClamp acc. DIN32676

Housing with split clamp flange, length 136 mm, flange diameter 85 mm with clamp 50.5 and 100 mm with clamp 64. On request with clamp ends or bio-plus® sterile union on the pipeline.

Groove Connection acc. DIN11864-3

aseptic, clamp 50.5 mmGroove Connection acc. DIN11864-3

Same design with aseptic groove connection acc. DIN11864-3, length 136 mm, flange diameter 85 mm.

Ingold 25

Ingold port on the pipeIngold 25

Pipe section with Ingold port 25 mm for sensors and plugs of the Ingold system, width 100 mm, port length 46 mm. Pipe connection with weld ends, clamp acc. DIN32676 or groove clamp ferrule acc. DIN11864-3.

Sizes

Same length, every nominal size.

Standard dimensions per measuring port. All versions are available for DIN04 to DIN40 and OD ¼" to OD 1½".

Measuring portPort ømmLengthmmFlange ømmISO
DIN3267650.513685ISO06–ISO40
DIN3267664136100ISO06–ISO40
DIN11864-350.513685ISO06–ISO40
Ingold2525100–ISO06–ISO40

Technical data

Materials, pressures, temperatures.

Nominal sizes
DIN04 to DIN40, ISO06 to ISO40, OD ¼" to OD 1½"; with clamp 50.5 also ISO pipes up to 76.1 mm outside diameter
Pipe connection dimensions
DIN11866 series A (DIN), series B (ISO), series C (OD)
Media
Gases and liquids
Operating pressure
12 bar
Product-contact materials
1.4435 (316L); special materials 1.4539, 2.4602, titanium, 1.4404; others on request
Gaskets
EPDM, silicone, FKM, PTFE, PTFE/silicone, PTFE/EPDM, PTFE/FKM; not included with clamp and DIN11864-3
Temperature by gasket
EPDM −40 to +150 °C, briefly 160 °C; FEP/silicone −60 to +200 °C, briefly 230 °C; FKM −20 to +200 °C, briefly 230 °C
Inside surface
Ra < 0.6 µm or Ra < 0.4 µm, electropolished; others on request
Welds
With clamp and DIN11864-3 unground inside and outside
Traceability
All product-contact parts marked with article number, material and heat number
Certificates
Inspection certificate 3.1 acc. EN10204 for product-contact parts; gaskets FDA conform, USP Class VI, TSE-free
Accessories
Clamp gaskets, end caps, sight glass caps; for Ingold 25 plugs, gasket sets and sight glass

Ordering key

Two keys, one range.

Examples: IGTC.R25.050.35.C — clamp acc. DIN32676, DIN25, clamp 50.5 mm, 1.4435 (316L), Ra < 0.6 µm electropolished. E25.L46.R25.SS.35.C — Ingold 25, port length 46 mm, DIN25, weld ends, 1.4435 BN2 (316L), Ra < 0.6 µm electropolished.

Clamp and DIN11864-3

  • IGTC: clamp acc. DIN32676
  • IGNC: groove connection acc. DIN11864-3
  • Clamp 50.5 mm as standard
  • Clamp 64, 34 or 25 mm as option

Ingold 25

  • E25: inline process port Ingold 25
  • L46: port length 46 mm
  • Pipe connection weld end
  • Clamp acc. DIN32676, ø25, 34, 50 or 64 mm
  • Groove clamp ferrule acc. DIN11864-3

For all

  • Pipe standard DIN, ISO or OD
  • Nominal size acc. table of pipe connections
  • Material 1.4435 (316L), 1.4539 or 2.4602; for Ingold 25 also 1.4404 or titanium
  • Ra < 0.6 or < 0.4 µm, electropolished

Contact

Enquiry

Tell us the measuring port, pipe standard, nominal size, pipe connection, material and surface as well as the sensor or accessory to be installed. We will propose the right version.

Prefer to write directly?

+41 55 450 83 00 sales@liquitec.ch